Posizionamento di protesi peniena malleabile. Risoluzione di complicanza intraoperatoria.

2009

ABSTRACT. We report a technique for the solution of an intraoperative complication occurred during penile prosthetic surgery. MATERIALS AND METHODS. A 70-year-old patient underwent open radical retropubic prostatectomy in 2004 due to a prostate cancer - Gleason 6 (3+3) pT2N0M0. The erectile dysfunction subsequently observed was not responsive to oral or intracavernosal drug administration, so a malleable penile implant surgery was recommended. RESULTS. During the positioning of the left penile cylinder, a septum perforation (cross-over) occurred. Instead of interrupting and postpone surgery in order to allow the septum to recover, we decided to proceed utilizing our technique for a safe pos…

Prostate cancer Erectile dysfunction Malleable prosthesis Septum perforationTumore prostatico Disfunzione erettile Protesi malleabili Perforazione setto intercavernosoSettore MED/24 - Urologia
researchProduct